AC Power Quality Monitor National ordering hotline:fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five

AC Power Quality Monitor

Product classification

contact us

Baoding Fangchang Electric Power Technology Co., Ltd
Tel: 0312-5952983
Fax: 0312-7520939
Website: www.bdsyfc.cn

Email: [email protected]
Address: Building D, Entrepreneurship Center, No. 295 Jingxiu Street, Gaokai District, Baoding City

Generalized reactive power compensation controller

Generalized reactive power compensation controller

  • Category:Generalized reactive power compensation controller

  • Number of clicks:
  • Release date:November 28, 2019
  • Online inquiry
  • Detailed introduction

       Power quality monitoringGWK-10 produced by the manufacturerGeneralized reactive power compensation controllerFunction Introduction
This controller is used for automatic adjustment of capacitor compensation devices in low-voltage distribution systems, and can control the switching of 10 sets of capacitors based on the set comprehensive power factor.
The output circuit adopts a cyclic working mode of first on, first off, and first on. The capacitor can also be switched on or off according to the set sequence.
The instrument can measure and display the comprehensive power factor, active power, reactive power, effective value of voltage fundamental wave, total voltage distortion rate, content of voltage 2-25th harmonic, effective value of current fundamental wave, total effective value of current harmonic, effective value of current 2-25th harmonic in real-time, and can provide advanced indication.
When there is overvoltage, overcurrent, harmonic voltage exceeding the limit, or harmonic current exceeding the limit, all capacitor banks are cut off and an indication of exceeding the limit is given. When there is undercurrent, an indication of exceeding the limit is given, and only the cut off judgment is made without any input action.
Technical indicators
Parameter setting: Please refer to the section on parameter code table and setting range for details.
Current measurement range: ≤ 10A.
Harmonic analysis range: 00-25th harmonic.
Fundamental error: ≤ ± 1%; harmonic error: ≤ ± 8%.
Capacitor switching relay node capacity: 220V, 3A.
Working voltage: 220V, 50Hz.
Environmental temperature: -10C -+50C.
Relative humidity: not greater than 80% at a temperature of+50C.
External dimensions (width, height, depth): 162mm105mm193mm
Installation of controllers
The controller is a screen mounted structure, and the device is installed on the already perforated screen. Install the brackets on both sides, and tighten the screws.




Opening size: 165 (W) 105 (H) mm

Reactive power compensation controller

This article's website:/product/577.html

Keywords:Reactive power compensation controller,Price of reactive power compensation controller,Manufacturer of reactive power compensation controller

Previous article: No more
Next article:Reactive power compensation monitoring terminal

Related products:

Related news:

Ji Gong Wang An Bei No. 130602020000978

  • Online Service
  • Contact number
    fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five
  • Online Message
  • Online consultation