AC Power Quality Monitor National ordering hotline:fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five

AC Power Quality Monitor

Product classification

contact us

Baoding Fangchang Electric Power Technology Co., Ltd
Tel: 0312-5952983
Fax: 0312-7520939
Website: www.bdsyfc.cn

Email: [email protected]
Address: Building D, Entrepreneurship Center, No. 295 Jingxiu Street, Gaokai District, Baoding City

AC Power Quality Monitor

Your current location: home page >> Product display >> AC Power Quality Monitor

AC Power Quality Monitor

  • Category:AC Power Quality Monitor

  • Number of clicks:
  • Release date:March 23, 2022
  • Online inquiry
  • Detailed introduction

Product Overview
SF DZ-3AC Power Quality MonitorIt can be applied to substations of various voltage levels in the power system and power supply and distribution systems of industrial and mining enterprisesPower quality monitoringAccording to the analysis, this series of products strictly comply with the relevant technical standards issued by the country, and their performance indicators meet the requirements of IEC61000-4-30 Class A instrument performance. At the same time, they meet the requirements of the latest national standard for power quality for measuring various indicators.

Product Features
◆ Adopting high-performance embedded industrial control boards and TI's 32-bit DSP as the core, with data processing capabilities, logic, and control capabilities, the core hardware is at the advanced level in China;
Adopting a multi CPU structure, each channel has a unique 32-bit DSP, ensuring real-time and accurate power quality data;
◆ Industrial grade DOM storage, using compression algorithms, data can be saved for more than a year, and real-time data is not lost when powered down;
◆ Adopting GPS synchronous sampling technology to ensure synchronous sampling of monitoring devices within the same substation or different substations;
◆ Data sampling: Each channel has a unique 16 bit parallel A/D, and all channels are fully synchronized for sampling, resulting in higher accuracy and faster speed;
◆ Adopting hardware phase-locked loop technology and automatic frequency tracking to prevent the impact of frequency changes on monitoring indicators in the power system and prevent frequency "leakage";
◆ Adopting a 5.7 inch large screen color LCD display, using an embedded operating system as the software platform, all software is programmed using VC++high-level language, ensuring high reliability and portability of the system;
◆ Microcomputer protection with back plug structure, channel expansion board supporting hot swapping, and simple installation;
Product Features

Basic monitoring quantity

Effective values of frequency, voltage, current, total active and reactive power, power factor

Basic monitoring indicators

Grid frequency, effective value of voltage/current, total active/reactive/power factor, effective value of three-phase fundamental voltage/current, phase of fundamental voltage/current, fundamental power/power factor, voltage deviation, frequency deviation, three-phase voltage imbalance, three-phase current imbalance, negative sequence component, harmonic (2-63 times), including total harmonic distortion rate of voltage and current, harmonic content, amplitude, phase angle, harmonic active Harmonic reactive power, harmonic apparent power, etc

Advanced monitoring indicators

Voltage fluctuations, flicker, interharmonics, subharmonics, voltage surges, voltage dips, overvoltage, undervoltage, short-term interruptions.

Other functions

Parameter setting function
Record storage function
GPS time synchronization function, using GPS B code time synchronization method; System timing.
Power loss alarm function

Technical indicators

technical specifications

Parameter indicators

Manufacturer

Baoding Fangchang Electric Power Technology Co., Ltd

Equipment model

SF DZ-3

Number of sampling paths

1X3Phase voltage, 1X3 phase current

Voltage measurement range

AC10~400V

Current measurement range

zero point zero five~5A

Frequency measurement range

forty-two point five~60Hz

Grid frequency error

≤0.002 Hz

Voltage deviation error

≤ 0.2%

Voltage fluctuation error

≤ 0.2%

Flicker error

≤ 5%

Error in three-phase voltage imbalance

≤ 0.2%

Harmonic measurement error

Meet the requirements of national standard A-level instruments

Interharmonic measurement error

Meet the requirements of national standard A-level instruments

Power error

≤ 0.5%

Display screen

five point sixInch TFT color LCD screen

Working power supply

AC220V± 20% frequency 45Hz~55Hz
DC110V/220V±20%

Communication interface; Communication protocol

Support RS232/RS485/Ethernet port;
Supports ModBus RTU and IEC60870-5-103 communication protocols

power dissipation

<20W

Working temperature/humidity

Working temperature -20 ℃~+60 ℃, humidity 5%~95% (non condensing)

size

1/2 19" 6UBackplug chassis; 19 "4U back plug-in chassis

weight

About 2kg

Installation method

Embedded


This article's website:/product/586.html

Keywords:Online monitoring device for power quality,Power quality,Power quality monitoring

Recent Views:

Ji Gong Wang An Bei No. 130602020000978

  • Online Service
  • Contact number
    fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five
  • Online Message
  • Online consultation