Main characteristics of power quality monitoring devices

Your current location: home page >> News and information >> Industry News

Main characteristics of power quality monitoring devices

Release date:April 23, 2019 Author: Click:

       Power quality monitoring deviceWhat are the characteristics?
1. Equipped with GPRS wireless transmission function and Ethernet remote transmission function, real-time data of each monitoring point can be obtained anytime and anywhere. Through remote control technology, it is possible to modify and set any monitoring point at any time and perform special tests.
2. You can view the data recorded by ZS3590 anywhere and at any time, and conduct detailed and in-depth analysis on the upper computer.
3. If there is an abnormal power event, ZS3590 can provide an alarm prompt at a faster speed, and through the original data, the equipment number and location of the problem can be quickly identified on the computer.
4. Built in large capacity Flash storage disk, ensuring the length of recording time and the integrity of recorded data.
5. Measurable range

Power quality monitoring device

Measurement accuracy description
Voltage/current/frequency three-phase voltage: 10~700V (true effective value)
Zero line voltage: 1~70V (true effective value)
Three phase current: 0~(true effective value, optional current sensor)
Zero line current: 0~(true effective value, optional current sensor)
Frequency: 40-70Hz Voltage: ± 0.5%
Current: ± 0.5%
Frequency: ± 0.01Hz Here, the A-phase voltage frequency is used as the measurement frequency
Harmonic measurement voltage harmonics: total harmonics, 1-50 harmonics
Current harmonic: total harmonic, 1-50th harmonic, voltage harmonic: ± 0.1 (% f)
Current harmonic: ± 1%
Power measurement active power: 0.05-700KW
Apparent: 0.05-700KVA
Reactive power: 0.05-700KVAR
Power factor: 0.00~1.00
Active energy: 0.01~10000kWh
Apparent electrical energy: 0.01~10000kVAh
Reactive energy: 0.01~10000kVARh
Average power factor: 0.00~1.00 Active power: ± 2%
Apparent: ± 2%
Reactive power: ± 2%
Power factor: reading ± 0.005
Active energy: ± 2%
Apparent electrical energy: ± 2%
Reactive energy: ± 2%
Average power factor: reading ± 0.005
Three phase unbalanced fundamental voltage: 10~700V (true effective value)
Fundamental current: 0.5~(true effective value)
Fundamental frequency: 40-70Hz
Phase angle: 0-360o
Unbalance: 0.0%~100% Voltage: 0.5% Current: 0.5%
Frequency: Reading ± 0.01Hz
Phase angle: reading ± 0.3 o
Voltage imbalance: reading ± 0.2 Current imbalance: reading ± 0.2 Here, the A-phase voltage frequency is used as the total measurement frequency

This article's website:/news/404.html

Keywords:Power quality monitoring,Power quality monitoring system,Online monitoring system for power quality

Ji Gong Wang An Bei No. 130602020000978

  • Online Service
  • Contact number
    fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five
  • Online Message
  • Online consultation