Differences between UPS batteries and inverters for power quality monitoring instruments

Your current location: home page >> News and information >> technical knowledge

Differences between UPS batteries and inverters for power quality monitoring instruments

Release date:April 23, 2019 Author: Click:

In the early daysAC Power Quality MonitorIn the computer room, the 220V AC power supply is usually rectified to charge the 48V battery pack, which directly supplies power to the program-controlled switch. With the application of computer networks and communication networks in telecommunications rooms, it is necessary to provide high-quality 220V AC power supply. Due to the existing 48V battery pack, the method of battery pack+inverter is usually used to convert 48V DC into 220V AC power supply for network power supply.


Power quality monitoringIn the instrument room, the important role of UPS (Uninterruptible Power Supply System) is uninterrupted power supply. When the municipal power grid meets the input range, it undergoes AC/DC and DC/AC dual conversion to supply power to the load. When the municipal power grid exceeds the limit, the battery supplies power to the load. When the UPS fails or is overloaded, the bypass power supply supplies power to the load. During maintenance, UPS can also be maintained online by manually repairing the bypass switch. The power supply method of battery pack+inverter must interrupt the system when the battery pack fails and needs to be replaced, which will cause huge losses to the system. The uninterrupted function of UPS is irreplaceable for battery packs and inverters.


The role of UPS in the power quality monitoring instrument room is to achieve uninterrupted mutual switching of dual power supplies, providing a certain amount of backup time, voltage stabilization, frequency stabilization, isolation of interference, etc. It can block grid disturbances such as instantaneous interruptions, harmonic interference, voltage fluctuations, frequency fluctuations, surges, etc. before the load. Due to the lack of direct electrical connection between the input DC bus and external battery pack of the UPS inverter and the user's original 48V communication power supply, there will be no conducted interference on the programmable controller.


In addition, to prevent external radiation interference, UPS usually adopts a steel plate frame structure, with a streamlined plastic shell designed outside the UPS lined with 2mm thick stainless steel plate. While maintaining a beautiful appearance, it eliminates radiation interference to other equipment. RFI filters are used at its input and output terminals, providing purified AC power to the load.


AC Power Quality Monitor


This article's website:/news/391.html

Keywords:Online power quality monitoring,Online monitoring instrument for power quality,Portable power quality analyzer

Previous article: No more
Next article:The purpose of power quality monitoring devices

Ji Gong Wang An Bei No. 130602020000978

  • Online Service
  • Contact number
    fifteen billion eight hundred and three million one hundred and twenty-five thousand five hundred and sixty-five
  • Online Message
  • Online consultation